Product Description
Key Features
-
Compact True-RMS digital multimeter designed for field service technicians
-
Includes: Fluke 115 meter, protective holster, and 4 mm PVC-insulated test leads
-
Easy one-handed operation
-
Min/Max/Average function to record signal fluctuations
-
Backlit display with large, easy-to-read 6000-count digits
Product Overview
The Fluke 115 Field Technicians Digital Multimeter is a compact and reliable True-RMS device designed to meet the needs of professionals working in the field. It accurately measures True-RMS voltage, current, resistance, continuity, capacitance, and frequency, ensuring dependable performance in every environment.
This multimeter supports one-handed operation and features a bright backlit display that enhances visibility in low-light areas. Its Min/Max/Average recording capability helps technicians capture signal variations over time.
Measurement ranges include:
-
AC/DC Voltage up to 600 V
-
AC/DC Current up to 10 A (with 20 A overload for 30 seconds)
Robust, portable, and built to Fluke standards, the 115 is the perfect choice for service technicians, electricians, and maintenance professionals.
Specifications
Accuracy Specifications
DC Millivolts
-
Range/Resolution: 600.0 mV / 0.1 mV
-
Accuracy: ±(0.5% + 2)
DC Volts
-
Ranges: 6.000 V / 0.001 V; 60.00 V / 0.01 V; 600.0 V / 0.1 V
-
Accuracy: ±(0.5% + 2)
AC Millivolts – True RMS
-
Range: 600.0 mV / 0.1 mV
-
Accuracy:
-
1.0% + 3 (DC, 45 Hz to 500 Hz)
-
2.0% + 3 (500 Hz to 1 kHz)
-
AC Volts – True RMS
-
Ranges: 6.000 V / 0.001 V; 60.00 V / 0.01 V; 600.0 V / 0.1 V
-
Accuracy:
-
1.0% + 3 (DC, 45 Hz to 500 Hz)
-
2.0% + 3 (500 Hz to 1 kHz)
-
Continuity
-
Range: 600 Ω / 1 Ω
-
Beeper: On < 20 Ω, Off > 250 Ω
Resistance (Ohms)
-
Ranges: 600.0 Ω to 40.00 MΩ
-
Accuracy:
-
Up to 6 MΩ: 0.9% + 1
-
40 MΩ: 5% + 2
-
Diode Test
-
Range: 2.00 V / 0.001 V
-
Accuracy: 0.9% + 2
Capacitance
-
Ranges: 1000 nF to 9999 µF
-
Accuracy:
-
Up to 1000 µF: 1.9% + 2
-
1000 µF: 5% + 20%
-
Lo-Z Capacitance
-
Range: 1 nF to 500 µF
-
Accuracy: 10% + 2 typical
AC Current – True RMS
-
Ranges: 6.000 A / 0.001 A and 10.00 A / 0.01 A
-
Accuracy: 1.5% + 3
-
Overload: 20 A for 30 seconds
DC Current
-
Ranges: 6.000 A / 0.001 A and 10.00 A / 0.01 A
-
Accuracy: 1.0% + 3
-
Overload: 20 A for 30 seconds
Frequency (V or A Input)
-
Ranges: 99.99 Hz to 50.00 kHz
-
Accuracy: 0.1% + 2
General Specifications
-
Maximum Voltage: 600 V between any terminal and earth ground
-
Safety Rating:
-
IEC 61010-1, Pollution Degree 2
-
IEC 61010-2-033: CAT III 600 V
-
-
Display: 6000-count digital, 4 updates/sec
-
Bar Graph: 33 segments, 32 updates/sec
-
Operating Temperature: -10°C to +50°C
-
Storage Temperature: -40°C to +60°C
-
Battery: 9V Alkaline, approx. 400-hour life (without backlight)
-
Dimensions: 167 × 84 × 46 mm
-
Weight: 550 g
-
Warranty: 3 years