Product Description
Key Features
-
Expands AC current measurement range up to 2500 A AC
-
Direct connection to compatible Fluke meters – no scaling factors required
-
CAT IV 600 V / CAT III 1000 V safety rating
-
7.5 mm thin coil diameter for tight and crowded spaces
-
Large loop size for measuring awkward or oversized conductors
-
1.8 m (6 ft) cable allows safe distance between measurement point and display
-
Ergonomic design enables easy one-handed operation
-
Excellent external magnetic field rejection
-
Backed by Fluke 3-year warranty
Product Overview
The Fluke i2500-18 iFlex® Flexible Current Probe is designed to enhance the versatility of compatible Fluke clamp meters by extending their AC current measurement capability up to 2500 amperes. Unlike traditional clamp jaws, the flexible Rogowski coil allows you to measure large conductors, bus bars, and cables in confined or hard-to-reach spaces with ease.
The thin 7.5 mm coil provides improved wire access in crowded panels, while the 1.8-meter cable enables safe and comfortable viewing of the meter display away from live conductors. With direct meter connection, readings are displayed accurately without error-prone scaling calculations.
Available in 45 cm (18 in) loop size, the i2500-18 is ideal for industrial maintenance, electrical troubleshooting, power distribution, and high-current applications.
Technical Specifications
Electrical Specifications
| Parameter | Specification |
|---|---|
| AC Current Range | 2500 A |
| Resolution | 0.1 A |
| Accuracy | ±3% ±5 digits |
| Frequency Range | Up to 500 Hz |
| Frequency Resolution | 0.1 Hz |
| Frequency Accuracy | ±0.5% ±5 digits |
| Inrush Current Measurement | Supported |
| External Magnetic Field Rejection | 40 dB (cable >10 cm from coupling) |
Safety
| Parameter | Rating |
|---|---|
| Safety Rating | CAT III 1000 V, CAT IV 600 V |
Physical Specifications
| Parameter | Specification |
|---|---|
| Coil Diameter | 7.5 mm |
| Loop Size | 45 cm (18 in) |
| Cable Length | 1.8 m (6 ft) |
| Operation | One-hand ergonomic design |
Position Sensitivity (Additional iFlex® Error)
| Distance from Optimum | i2500-18 Error |
|---|---|
| 35.6 mm (1.4 in) | ±0.5% |
| 50.8 mm (2.0 in) | ±1.0% |
| 63.5 mm (2.5 in) | ±2.0% |
Applications
-
Industrial electrical maintenance
-
High-current measurements in power distribution systems
-
Motor control centers (MCCs)
-
Utilities and substations
-
HVAC and large electrical installations
-
Crowded panels and confined spaces
What’s in the Box
-
Fluke i2500-18 iFlex® Flexible Current Probe
-
User documentation
Warranty
-
3-Year Manufacturer Warranty